summaryrefslogtreecommitdiff
path: root/man/sd_bus_set_connected_signal.xml
blob: a439c2e6085fbda969b372e0822a6973ebf6494e (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
<?xml version='1.0'?> <!--*- Mode: nxml; nxml-child-indent: 2; indent-tabs-mode: nil -*-->
<!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.2//EN"
"http://www.oasis-open.org/docbook/xml/4.2/docbookx.dtd">

<!--
  SPDX-License-Identifier: LGPL-2.1+
-->

<refentry id="sd_bus_set_connected_signal">

  <refentryinfo>
    <title>sd_bus_set_connected_signal</title>
    <productname>elogind</productname>
  </refentryinfo>

  <refmeta>
    <refentrytitle>sd_bus_set_connected_signal</refentrytitle>
    <manvolnum>3</manvolnum>
  </refmeta>

  <refnamediv>
    <refname>sd_bus_set_connected_signal</refname>
    <refname>sd_bus_get_connected_signal</refname>

    <refpurpose>Control emmission of local connection establishment signal on bus connections</refpurpose>
  </refnamediv>

  <refsynopsisdiv>
    <funcsynopsis>
      <funcsynopsisinfo>#include &lt;elogind/sd-bus.h&gt;</funcsynopsisinfo>

      <funcprototype>
        <funcdef>int <function>sd_bus_set_connected_signal</function></funcdef>
        <paramdef>sd_bus *<parameter>bus</parameter></paramdef>
        <paramdef>int <parameter>b</parameter></paramdef>
      </funcprototype>

      <funcprototype>
        <funcdef>int <function>sd_bus_get_connected_signal</function></funcdef>
        <paramdef>sd_bus *<parameter>bus</parameter></paramdef>
      </funcprototype>

    </funcsynopsis>
  </refsynopsisdiv>

  <refsect1>
    <title>Description</title>

    <para><function>sd_bus_set_connected_signal()</function> may be used to control whether a local, synthetic
    <function>Connected()</function> signal message shall be generated and enqueued for dispatching when the connection
    is fully established. If the <parameter>b</parameter> parameter is zero the message is not generated (the default),
    otherwise it is generated.</para>

    <para><function>sd_bus_get_connected_signal()</function> may be used to query whether this feature is enabled. It
    returns zero if not, positive otherwise.</para>

    <para>The <function>Connected()</function> signal message is generated from the
    <literal>org.freedesktop.DBus.Local</literal> service and interface, and
    <literal>/org/freedesktop/DBus/Local</literal> object path. Use
    <citerefentry><refentrytitle>sd_bus_match_signal_async</refentrytitle><manvolnum>3</manvolnum></citerefentry> to
    match on this signal.</para>

    <para>This message is particularly useful on slow transports where connections take a long time to be
    established. This is especially the case when
    <citerefentry><refentrytitle>sd_bus_set_watch_bind</refentrytitle><manvolnum>3</manvolnum></citerefentry> is
    used. The signal is generated when the
    <citerefentry><refentrytitle>sd_bus_is_ready</refentrytitle><manvolnum>3</manvolnum></citerefentry> returns
    positive for the first time.</para>

    <para>The <function>Connected()</function> signal corresponds with the <function>Disconnected()</function> signal
    that is synthesized locally when the connection is terminated. The latter is generated unconditionally however,
    unlike the former which needs to be enabled explicitly before it is generated, with
    <function>sd_bus_set_connected_signal()</function>.</para>
  </refsect1>

  <refsect1>
    <title>Return Value</title>

    <para>On success, these functions return 0 or a positive integer. On failure, they return a negative errno-style
    error code.</para>
  </refsect1>

  <refsect1>
    <title>Errors</title>

    <para>Returned errors may indicate the following problems:</para>

    <variablelist>
      <varlistentry>
        <term><constant>-ECHILD</constant></term>

        <listitem><para>The bus connection has been created in a different process.</para></listitem>
      </varlistentry>
    </variablelist>
  </refsect1>

  <refsect1>
    <title>Notes</title>

    <para><function>sd_bus_set_connected_signal()</function> and <function>sd_bus_get_connected_signal()</function> are available as
    a shared library, which can be compiled and linked to with the <constant>libelogind</constant> <citerefentry
    project='die-net'><refentrytitle>pkg-config</refentrytitle><manvolnum>1</manvolnum></citerefentry> file.</para>
  </refsect1>

  <refsect1>
    <title>See Also</title>

    <para>
      <citerefentry><refentrytitle>elogind</refentrytitle><manvolnum>1</manvolnum></citerefentry>,
      <citerefentry><refentrytitle>sd-bus</refentrytitle><manvolnum>3</manvolnum></citerefentry>,
      <citerefentry><refentrytitle>sd_bus_match_signal_async</refentrytitle><manvolnum>3</manvolnum></citerefentry>,
      <citerefentry><refentrytitle>sd_bus_set_watch_bind</refentrytitle><manvolnum>3</manvolnum></citerefentry>,
      <citerefentry><refentrytitle>sd_bus_is_ready</refentrytitle><manvolnum>3</manvolnum></citerefentry>
    </para>
  </refsect1>

</refentry>