summaryrefslogtreecommitdiff
path: root/man/sd_bus_slot_set_floating.xml
blob: a2a134e9f418d05b8f9486a7f46c684a98028fc5 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
<?xml version='1.0'?> <!--*- Mode: nxml; nxml-child-indent: 2; indent-tabs-mode: nil -*-->
<!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.2//EN"
"http://www.oasis-open.org/docbook/xml/4.2/docbookx.dtd">

<!-- SPDX-License-Identifier: LGPL-2.1+ -->

<refentry id="sd_bus_slot_set_floating" xmlns:xi="http://www.w3.org/2001/XInclude">

  <refentryinfo>
    <title>sd_bus_slot_set_floating</title>
    <productname>elogind</productname>
  </refentryinfo>

  <refmeta>
    <refentrytitle>sd_bus_slot_set_floating</refentrytitle>
    <manvolnum>3</manvolnum>
  </refmeta>

  <refnamediv>
    <refname>sd_bus_slot_set_floating</refname>
    <refname>sd_bus_slot_get_floating</refname>

    <refpurpose>Control whether a bus slot object is "floating".</refpurpose>
  </refnamediv>

  <refsynopsisdiv>
    <funcsynopsis>
      <funcsynopsisinfo>#include &lt;elogind/sd-bus.h&gt;</funcsynopsisinfo>

      <funcprototype>
        <funcdef>int <function>sd_bus_slot_set_floating</function></funcdef>
        <paramdef>sd_bus_slot *<parameter>slot</parameter></paramdef>
        <paramdef>int <parameter>b</parameter></paramdef>
      </funcprototype>

      <funcprototype>
        <funcdef>int <function>sd_bus_slot_get_floating</function></funcdef>
        <paramdef>sd_bus_slot *<parameter>slot</parameter></paramdef>
      </funcprototype>

    </funcsynopsis>
  </refsynopsisdiv>

  <refsect1>
    <title>Description</title>

    <para><function>sd_bus_slot_set_floating()</function> controls whether the specified bus slot object
    <parameter>slot</parameter> shall be "floating" or not. A floating bus slot object's lifetime is bound to the
    lifetime of the bus object it is associated with, meaning that it remains allocated as long as the bus object
    itself and is freed automatically when the bus object is freed. Regular (i.e. non-floating) bus slot objects keep
    the bus referenced, hence the bus object remains allocated at least as long as there remains at least one
    referenced bus slot object around. The floating state hence controls the direction of referencing between the bus
    object and the bus slot objects: if floating the bus pins the bus slot, and otherwise the bus slot pins the bus
    objects. Use <function>sd_bus_slot_set_floating()</function> to switch between both modes: if the
    <parameter>b</parameter> parameter is zero, the slot object is considered floating, otherwise it is made a regular
    (non-floating) slot object.</para>

    <para>Bus slot objects may be allocated with calls such as
    <citerefentry><refentrytitle>sd_bus_add_match</refentrytitle><manvolnum>3</manvolnum></citerefentry>. If the
    <parameter>slot</parameter> of these functions is non-<constant>NULL</constant> the slot object will be of the
    regular kind (i.e. non-floating), otherwise it will be created floating. With
    <function>sd_bus_slot_set_floating()</function> a bus slot object allocated as regular can be converted into a
    floating object and back. This is particularly useful for creating a bus slot object, then changing parameters of
    it, and then turning it into a floating object, whose lifecycle is managed by the bus object.</para>

    <para><function>sd_bus_slot_get_floating()</function> returns the current floating state of the specified bus slot
    object. It returns negative on error, zero if the bus slot object is a regular (non-floating) object and positive
    otherwise.</para>
  </refsect1>

  <refsect1>
    <title>Return Value</title>

    <para>On success, these functions return 0 or a positive integer. On failure, they return a negative errno-style
    error code.</para>
  </refsect1>

  <refsect1>
    <title>Errors</title>

    <para>Returned errors may indicate the following problems:</para>

    <variablelist>
      <varlistentry>
        <term><constant>-EINVAL</constant></term>

        <listitem><para>The <parameter>slot</parameter> parameter is <constant>NULL</constant>.</para></listitem>
      </varlistentry>

      <varlistentry>
        <term><constant>-ECHILD</constant></term>

        <listitem><para>The bus connection has been created in a different process.</para></listitem>
      </varlistentry>

      <varlistentry>
        <term><constant>-ESTALE</constant></term>

        <listitem><para>The bus object the specified bus slot object is associated with has already been freed, and
        hence no change in the floating state can be made anymore.</para></listitem>
      </varlistentry>
    </variablelist>
  </refsect1>

  <xi:include href="libelogind-pkgconfig.xml" />

  <refsect1>
    <title>See Also</title>

    <para>
      <citerefentry><refentrytitle>elogind</refentrytitle><manvolnum>1</manvolnum></citerefentry>,
      <citerefentry><refentrytitle>sd-bus</refentrytitle><manvolnum>3</manvolnum></citerefentry>,
      <citerefentry><refentrytitle>sd_bus_slot_set_destroy_callback</refentrytitle><manvolnum>3</manvolnum></citerefentry>,
      <citerefentry><refentrytitle>sd_bus_add_match</refentrytitle><manvolnum>3</manvolnum></citerefentry>
    </para>
  </refsect1>

</refentry>