diff options
author | Dimitri John Ledkov <xnox@debian.org> | 2015-11-08 11:48:28 +0000 |
---|---|---|
committer | Dimitri John Ledkov <xnox@debian.org> | 2015-11-08 11:48:28 +0000 |
commit | 948fb73b04fa9b0f9a9e81e08040b79b65826a16 (patch) | |
tree | 596ca722473e5e56bdd137762ae60723b176c440 /mdadm.8.in | |
parent | 489bea7ee8e1dbecfa517b8415568044ab57c73a (diff) |
New upstream release.
Diffstat (limited to 'mdadm.8.in')
-rw-r--r-- | mdadm.8.in | 31 |
1 files changed, 19 insertions, 12 deletions
@@ -5,7 +5,7 @@ .\" the Free Software Foundation; either version 2 of the License, or .\" (at your option) any later version. .\" See file COPYING in distribution for details. -.TH MDADM 8 "" v3.3.2 +.TH MDADM 8 "" v3.3.4 .SH NAME mdadm \- manage MD devices .I aka @@ -214,7 +214,7 @@ to detect and assemble arrays \(em possibly in an .P If a device is given before any options, or if the first option is -and of +one of .BR \-\-add , .BR \-\-re\-add , .BR \-\-add\-spare , @@ -267,13 +267,13 @@ the exact meaning of this option in different contexts. .TP .BR \-c ", " \-\-config= Specify the config file or directory. Default is to use -.B /etc/mdadm/mdadm.conf +.B /etc/mdadm.conf and -.BR /etc/mdadm/mdadm.conf.d , +.BR /etc/mdadm.conf.d , or if those are missing then -.B /etc/mdadm.conf +.B /etc/mdadm/mdadm.conf and -.BR /etc/mdadm.conf.d . +.BR /etc/mdadm/mdadm.conf.d . If the config file given is .B "partitions" then nothing will be read, but @@ -393,6 +393,13 @@ will be allowed to use 'local' names (i.e. not ending in '_' followed by a digit string). See below under .BR "Auto Assembly" . +The special name "\fBany\fP" can be used as a wild card. If an array +is created with +.B --homehost=any +then the name "\fBany\fP" will be stored in the array and it can be +assembled in the same way on any host. If an array is assembled with +this option, then the homehost recorded on the array will be ignored. + .TP .B \-\-prefer= When @@ -1796,9 +1803,9 @@ The config file is only used if explicitly named with or requested with (a possibly implicit) .BR \-\-scan . In the later case, -.B /etc/mdadm/mdadm.conf -or .B /etc/mdadm.conf +or +.B /etc/mdadm/mdadm.conf is used. If @@ -2196,11 +2203,11 @@ option. Currently only .B name is supported. -The +The .B name option updates the subarray name in the metadata, it may not affect the device node name or the device node symlink until the subarray is -re\-assembled. If updating +re\-assembled. If updating .B name would change the UUID of an active subarray this operation is blocked, and the command will end in an error. @@ -3092,7 +3099,7 @@ uses this to find arrays when is given in Misc mode, and to monitor array reconstruction on Monitor mode. -.SS /etc/mdadm/mdadm.conf (or /etc/mdadm.conf) +.SS /etc/mdadm.conf The config file lists which devices may be scanned to see if they contain MD super block, and gives identifying information @@ -3100,7 +3107,7 @@ they contain MD super block, and gives identifying information .BR mdadm.conf (5) for more details. -.SS /etc/mdadm/mdadm.conf.d (or /etc/mdadm.conf.d) +.SS /etc/mdadm.conf.d A directory containing configuration files which are read in lexical order. |