summaryrefslogtreecommitdiff
path: root/misc/yosys.proto
blob: a583e6265cf2b2eb823fdf108821eb7063f6859e (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
//
// yosys -- Yosys Open SYnthesis Suite
//
// Copyright (C) 2018  Serge Bazanski <q3k@symbioticeda.com>
//
// Permission to use, copy, modify, and/or distribute this software for any
// purpose with or without fee is hereby granted, provided that the above
// copyright notice and this permission notice appear in all copies.
//
// THE SOFTWARE IS PROVIDED "AS IS" AND THE AUTHOR DISCLAIMS ALL WARRANTIES
// WITH REGARD TO THIS SOFTWARE INCLUDING ALL IMPLIED WARRANTIES OF
// MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR
// ANY SPECIAL, DIRECT, INDIRECT, OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES
// WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, WHETHER IN AN
// ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF
// OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS SOFTWARE.
//

/// Protobuf definition of Yosys RTLIL dump/restore format for RTL designs.

syntax = "proto3";

package yosys.pb;

// Port direction.
enum Direction {
    DIRECTION_INVALID = 0;
    DIRECTION_INPUT = 1;
    DIRECTION_OUTPUT = 2;
    DIRECTION_INOUT = 3;
}

// A freeform parameter/attribute value.
message Parameter {
    oneof value {
        int64 int = 1;
        string str = 2;
    }
}

// A signal in the design - either a unique identifier for one, or a constant
// driver (low or high).
message Signal {
    // A constant signal driver in the design.
    enum ConstantDriver {
        CONSTANT_DRIVER_INVALID = 0;
        CONSTANT_DRIVER_LOW = 1;
        CONSTANT_DRIVER_HIGH = 2;
        CONSTANT_DRIVER_Z = 3;
        CONSTANT_DRIVER_X = 4;
    }
    oneof type {
        // Signal uniquely identified by ID number.
        int64 id = 1;
        // Constant driver.
        ConstantDriver constant = 2;
    }
}

// A vector of signals.
message BitVector {
    repeated Signal signal = 1;
}

// A netlist module.
message Module {
    // Freeform attributes.
    map<string, Parameter> attribute = 1;

    // Named ports in this module.
    message Port {
        Direction direction = 1;
        BitVector bits = 2;
    }
    map<string, Port> port = 2;

    // Named cells in this module.
    message Cell {
        // Set to true when the name of this cell is automatically created and
        // likely not of interest for a regular user.
        bool hide_name = 1;
        string type = 2;
        // Set if this module has an AIG model available.
        string model = 3;
        // Freeform parameters.
        map<string, Parameter> parameter = 4;
        // Freeform attributes.
        map<string, Parameter> attribute = 5;

        /// Ports of the cell.
        // Direction of the port, if interface is known.
        map<string, Direction> port_direction = 6;
        // Connection of named port to signal(s).
        map<string, BitVector> connection = 7;
    }
    map<string, Cell> cell = 3;

    // Nets in this module.
    message Netname {
        // Set to true when the name of this net is automatically created and
        // likely not of interest for a regular user.
        bool hide_name = 1;
        // Signal(s) that make up this net.
        BitVector bits = 2;
        // Freeform attributes.
        map<string, Parameter> attributes = 3;
    }
    repeated Netname netname = 4;
}

// And-Inverter-Graph model.
message Model {
    message Node {
        // Type of AIG node - or, what its' value is.
        enum Type {
            TYPE_INVALID = 0;
            // The node's value is the value of the specified input port bit.
            TYPE_PORT = 1;
            // The node's value is the inverted value of the specified input
            // port bit.
            TYPE_NPORT = 2;
            // The node's value is the ANDed value of specified nodes.
            TYPE_AND = 3;
            // The node's value is the NANDed value of specified nodes.
            TYPE_NAND = 4;
            // The node's value is a constant 1.
            TYPE_TRUE = 5;
            // The node's value is a constant 0.
            TYPE_FALSE = 6;
        };
        Type type = 1;

        message Port {
            // Name of port.
            string portname = 1;
            // Bit index in port.
            int64 bitindex = 2;
        }
        message Gate {
            // Node index of left side of operation.
            int64 left = 1;
            // Node index of right side of operation.
            int64 right = 2;
        }
        oneof node {
            // Set for PORT, NPORT
            Port port = 2;
            // Set for AND, NAND.
            Gate gate = 3;
        }

        // Set when the node drives given output port(s).
        message OutPort {
            // Name of port.
            string name = 1;
            // Bit index in port.
            int64 bit_index = 2;
        }
        repeated OutPort out_port = 4;
    }

    // List of  AIG nodes - each is explicitely numbered by its' index in this
    // array.
    repeated Node node = 1;
}

// A Yosys design netlist dumped from RTLIL.
message Design {
    // Human-readable freeform 'remark' string.
    string creator = 1;
    // List of named modules in design.
    map<string, Module> modules = 2;
    // List of named AIG models in design (if AIG export enabled).
    map<string, Model> models = 3;
}