summaryrefslogtreecommitdiff
path: root/man/sd_bus_set_connected_signal.xml
blob: 1dd39da50b2ea5a1e42f1963de4ab2dc8634d6ff (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
<?xml version='1.0'?> <!--*- Mode: nxml; nxml-child-indent: 2; indent-tabs-mode: nil -*-->
<!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.2//EN"
"http://www.oasis-open.org/docbook/xml/4.2/docbookx.dtd">

<!--
  SPDX-License-Identifier: LGPL-2.1+

  This file is part of elogind.

  Copyright 2017 Lennart Poettering

  elogind is free software; you can redistribute it and/or modify it
  under the terms of the GNU Lesser General Public License as published by
  the Free Software Foundation; either version 2.1 of the License, or
  (at your option) any later version.

  elogind is distributed in the hope that it will be useful, but
  WITHOUT ANY WARRANTY; without even the implied warranty of
  MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
  Lesser General Public License for more details.

  You should have received a copy of the GNU Lesser General Public License
  along with elogind; If not, see <http://www.gnu.org/licenses/>.
-->

<refentry id="sd_bus_set_connected_signal">

  <refentryinfo>
    <title>sd_bus_set_connected_signal</title>
    <productname>elogind</productname>

    <authorgroup>
      <author>
        <contrib>Developer</contrib>
        <firstname>Lennart</firstname>
        <surname>Poettering</surname>
        <email>lennart@poettering.net</email>
      </author>
    </authorgroup>
  </refentryinfo>

  <refmeta>
    <refentrytitle>sd_bus_set_connected_signal</refentrytitle>
    <manvolnum>3</manvolnum>
  </refmeta>

  <refnamediv>
    <refname>sd_bus_set_connected_signal</refname>
    <refname>sd_bus_get_connected_signal</refname>

    <refpurpose>Control emmission of local connection establishment signal on bus connections</refpurpose>
  </refnamediv>

  <refsynopsisdiv>
    <funcsynopsis>
      <funcsynopsisinfo>#include &lt;elogind/sd-bus.h&gt;</funcsynopsisinfo>

      <funcprototype>
        <funcdef>int <function>sd_bus_set_connected_signal</function></funcdef>
        <paramdef>sd_bus *<parameter>bus</parameter></paramdef>
        <paramdef>int <parameter>b</parameter></paramdef>
      </funcprototype>

      <funcprototype>
        <funcdef>int <function>sd_bus_get_connected_signal</function></funcdef>
        <paramdef>sd_bus *<parameter>bus</parameter></paramdef>
      </funcprototype>

    </funcsynopsis>
  </refsynopsisdiv>

  <refsect1>
    <title>Description</title>

    <para><function>sd_bus_set_connected_signal()</function> may be used to control whether a local, synthetic
    <function>Connected()</function> signal message shall be generated and enqueued for dispatching when the connection
    is fully established. If the <parameter>b</parameter> parameter is zero the message is not generated (the default),
    otherwise it is generated.</para>

    <para><function>sd_bus_get_connected_signal()</function> may be used to query whether this feature is enabled. It
    returns zero if not, positive otherwise.</para>

    <para>The <function>Connected()</function> signal message is generated from the
    <literal>org.freedesktop.DBus.Local</literal> service and interface, and
    <literal>/org/freedesktop/DBus/Local</literal> object path. Use
    <citerefentry><refentrytitle>sd_bus_match_signal_async</refentrytitle><manvolnum>3</manvolnum></citerefentry> to
    match on this signal.</para>

    <para>This message is particularly useful on slow transports where connections take a long time to be
    established. This is especially the case when
    <citerefentry><refentrytitle>sd_bus_set_watch_bind</refentrytitle><manvolnum>3</manvolnum></citerefentry> is
    used. The signal is generated when the
    <citerefentry><refentrytitle>sd_bus_is_ready</refentrytitle><manvolnum>3</manvolnum></citerefentry> returns
    positive for the first time.</para>

    <para>The <function>Connected()</function> signal corresponds with the <function>Disconnected()</function> signal
    that is synthesized locally when the connection is terminated. The latter is generated unconditionally however,
    unlike the former which needs to be enabled explicitly before it is generated, with
    <function>sd_bus_set_connected_signal()</function>.</para>
  </refsect1>

  <refsect1>
    <title>Return Value</title>

    <para>On success, these functions return 0 or a positive integer. On failure, they return a negative errno-style
    error code.</para>
  </refsect1>

  <refsect1>
    <title>Errors</title>

    <para>Returned errors may indicate the following problems:</para>

    <variablelist>
      <varlistentry>
        <term><constant>-ECHILD</constant></term>

        <listitem><para>The bus connection has been created in a different process.</para></listitem>
      </varlistentry>
    </variablelist>
  </refsect1>

  <refsect1>
    <title>Notes</title>

    <para><function>sd_bus_set_connected_signal()</function> and <function>sd_bus_get_connected_signal()</function> are available as
    a shared library, which can be compiled and linked to with the <constant>libelogind</constant> <citerefentry
    project='die-net'><refentrytitle>pkg-config</refentrytitle><manvolnum>1</manvolnum></citerefentry> file.</para>
  </refsect1>

  <refsect1>
    <title>See Also</title>

    <para>
      <citerefentry><refentrytitle>elogind</refentrytitle><manvolnum>1</manvolnum></citerefentry>,
      <citerefentry><refentrytitle>sd-bus</refentrytitle><manvolnum>3</manvolnum></citerefentry>,
      <citerefentry><refentrytitle>sd_bus_match_signal_async</refentrytitle><manvolnum>3</manvolnum></citerefentry>,
      <citerefentry><refentrytitle>sd_bus_set_watch_bind</refentrytitle><manvolnum>3</manvolnum></citerefentry>,
      <citerefentry><refentrytitle>sd_bus_is_ready</refentrytitle><manvolnum>3</manvolnum></citerefentry>
    </para>
  </refsect1>