+$quote "
+
+$set 0 Generic
+1 "Select one of the following"
+2 "Selection"
+3 "Complete"
+4 "to return to menu, current operations will continue"
+
+$set 101 main_menu
+1 "Work with Disk Units"
+2 "Display disk hardware status"
+3 "Work with Disk Arrays"
+4 "Work with disk unit recovery"
+5 "Work with SCSI bus configuration"
+6 "Work with driver configuration"
+7 "Analyze log"
+
+$set 102 disk_status
+1 "Display Disk Hardware Status"
+2 "Type option, press Enter."
+3 "Display hardware resource information details"
+4 "No devices found"
+
+$set 104 device_details
+1 "IOA Hardware Resource Information Details"
+2 "Manufacturer"
+3 "Machine Type and Model"
+4 "Driver Version"
+5 "Firmware Version"
+6 "Serial Number"
+7 "Part Number"
+8 "Plant of Manufacturer"
+9 "Cache Size"
+10 "DRAM Size"
+11 "Resource Name"
+12 "Physical location"
+13 "PCI Address"
+14 "SCSI Host Number"
+15 "Resource Path"
+
+101 "Disk Array Information Details"
+102 "RAID Level"
+103 "Stripe Size"
+104 "Capacity"
+
+201 "Disk Unit Hardware Resource Information Details"
+202 "Product ID"
+203 "SCSI Host Number"
+204 "SCSI Channel"
+205 "SCSI Id"
+206 "SCSI Lun"
+207 "Level"
+208 "Extended Details"
+209 "FRU Number"
+210 "EC Level"
+211 "Device Specific (Z0)"
+212 "Device Specific (Z1)"
+213 "Device Specific (Z2)"
+214 "Device Specific (Z3)"
+215 "Device Specific (Z4)"
+216 "Device Specific (Z5)"
+217 "Device Specific (Z6)"
+
+$set 200 raid_screen
+1 "Work with Disk Arrays"
+2 "Display disk array status"
+3 "Create a disk array"
+4 "Delete a disk array"
+5 "Add a device to a disk array"
+6 "Format device for advanced function"
+7 "Format device for JBOD function"
+8 "Configure a hot spare device"
+9 "Unconfigure a hot spare device"
+
+$set 201 raid_status
+1 "Display Disk Array Status"
+2 "Type option, press Enter."
+3 "Display hardware resource information details"
+4 "No devices found"
+
+$set 202 raid_start
+1 "Create a Disk Array"
+2 "Select the subsystems to create a disk array."
+3 "Type choice, press Enter."
+4 "create a disk array"
+
+$set 203 raid_stop
+1 "Delete a Disk Array"
+2 "Select the subsystems to delete a disk array."
+3 "Type choice, press Enter."
+4 "delete a disk array"
+
+$set 204 raid_stop_fail
+1 "Delete a Disk Array Failed"
+2 "There are no disk units eligible for the selected operation\
+ due to one or more of the following reasons:"
+3 "There are no device parity protected units in the system."
+4 "An IOA is in a condition that makes the disk units attached to\
+ it read/write protected. Examine the kernel messages log\
+ for any errors that are logged for the IO subsystem\
+ and follow the appropriate procedure for the reference code to\
+ correct the problem, if necessary."
+5 "Not all disk units attached to an advanced function IOA have\
+ reported to the system. Retry the operation."
+6 "The disk units are missing."
+7 "The disk unit/s are currently in use."
+
+$set 205 confirm_raid_stop
+1 "Confirm Delete a Disk Array"
+2 "ATTENTION: Disk units connected to these subsystems will not be\
+ protected after you confirm your choice."
+3 "Press Enter to continue."
+4 "Cancel to return and change your choice."
+
+$set 207 raid_start_fail
+1 "Create a Disk Array Failed"
+2 "There are no disk units eligible for the selected operation due\
+ to one or more of the following reasons:"
+3 "There are not enough device parity capable units in the system."
+4 "An IOA is in a condition that makes the disk units attached to\
+ it read/write protected. Examine the kernel messages log\
+ for any errors that are logged for the IO subsystem\
+ and follow the appropriate procedure for the reference code to\
+ correct the problem, if necessary."
+5 "Not all disk units attached to an advanced function IOA have\
+ reported to the system. Retry the operation."
+6 "The disk units are missing."
+7 "The disk unit/s are currently in use."
+
+$set 208 configure_raid_start
+1 "Select Disk Units for Parity Protection"
+2 "Type option, press Enter."
+3 "Select"
+
+$set 210 confirm_raid_start
+1 "Confirm Start Device Parity Protection"
+2 "ATTENTION: Data will not be preserved and may be lost on selected disk\
+ units when parity protection is enabled."
+3 "Press Enter to continue."
+4 "Cancel to return and change your choice."
+
+$set 211 raid_start_complete
+1 "Start Device Parity Protection Status"
+2 "You selected to start device parity protection"
+
+$set 215 raid_include
+1 "Add a Device to a Disk Array"
+2 "Select the subsystem that the disk unit will be included."
+3 "Type choice, press Enter."
+4 "Select Parity Array to Include Disk Unit"
+
+$set 216 raid_include_fail
+1 "Include Device Parity Protection Failed"
+2 "There are no disk units eligible for the selected operation\
+ due to one or more of the following reasons:"
+3 "There are no device parity protected units in the system."
+4 "An IOA is in a condition that makes the disk units attached to\
+ it read/write protected. Examine the kernel messages log\
+ for any errors that are logged for the IO subsystem\
+ and follow the appropriate procedure for the reference code to\
+ correct the problem, if necessary."
+5 "Not all disk units attached to an advanced function IOA have\
+ reported to the system. Retry the operation."
+6 "The disk units are missing."
+7 "The disk unit/s are currently in use."
+
+$set 217 configure_raid_include
+1 "Include Disk Units in Device Parity Protection"
+2 "Select the units to be included in Device Parity Protection"
+3 "Type choice, press Enter."
+4 "Add a Device to a Disk Array"
+
+$set 218 configure_raid_include_fail
+1 "Include Disk Unit Failed"
+2 "There are no disk units eligible for the selected operation\
+ due to one or more of the following reasons:"
+3 "There are not enough disk units available to be included."
+4 "The disk unit that needs to be included is not at the right\
+ location. Examine the 'message log' for the exposed unit\
+ and make sure that the replacement unit is at the correct\
+ location"
+5 "Not all disk units attached to an IOA have reported to the\
+ system. Retry the operation."
+6 "The disk unit to be included must be the same or greater\
+ capacity than the smallest device in the volume set and\
+ be formatted correctly"
+7 "The type/model of the disk units is not supported for the\
+ requested operation"
+
+$set 219 confirm_raid_include
+1 "Confirm Disk Units to be Included"
+2 "ATTENTION: All listed device units will be formatted and zeroed before\
+ listed device is added to array."
+3 "Press Enter to confirm your choice to have the system include\
+ the selected units in device parity protection"
+4 "Cancel to return and change your choice."
+
+$set 221 dev_include_complete
+1 "Include Disk Units in Device Parity Protection Status"
+2 "The operation to include units in the device parity protection\
+ will be done in two phases. The device must first be formatted\
+ before device may be included into array set."
+3 "You selected to include a device in a device parity set"
+
+$set 230 af_include_fail
+1 "Format Device for Advanced Function Failed"
+2 "There are no disk units eligible for the selected operation\
+ due to one or more of the following reasons:"
+3 "There are no eligible device units in the system."
+4 "An IOA is in a condition that makes the disk units attached to\
+ it read/write protected. Examine the kernel messages log\
+ for any errors that are logged for the IO subsystem\
+ and follow the appropriate procedure for the reference code to\
+ correct the problem, if necessary."
+5 "Not all disk units attached to an advanced function IOA have\
+ reported to the system. Retry the operation."
+6 "The disk units are missing."
+7 "The disk unit/s are currently in use."
+
+$set 231 af_remove_fail
+1 "Disable Device for Advanced Functions Failed"
+2 "There are no disk units eligible for the selected operation\
+ due to one or more of the following reasons:"
+3 "There are no eligible device units in the system."
+4 "An IOA is in a condition that makes the disk units attached to\
+ it read/write protected. Examine the kernel messages log\
+ for any errors that are logged for the IO subsystem\
+ and follow the appropriate procedure for the reference code to\
+ correct the problem, if necessary."
+5 "Not all disk units attached to an advanced function IOA have\
+ reported to the system. Retry the operation."
+6 "The disk units are missing."
+7 "The disk unit/s are currently in use."
+
+$set 232 add_hot_spare_fail
+1 "Enable Device as Hot Spare Failed"
+2 "There are no disk units eligible for the selected operation\
+ due to one or more of the following reasons:"
+3 "There are no eligible device units in the system."
+4 "An IOA is in a condition that makes the disk units attached to\
+ it read/write protected. Examine the kernel messages log\
+ for any errors that are logged for the IO subsystem\
+ and follow the appropriate procedure for the reference code to\
+ correct the problem, if necessary."
+5 "Not all disk units attached to an advanced function IOA have\
+ reported to the system. Retry the operation."
+6 "The disk units are missing."
+7 "The disk unit/s are currently in use."
+
+$set 233 remove_hot_spare_fail
+1 "Disable Device as Hot Spare Failed"
+2 "There are no disk units eligible for the selected operation\
+ due to one or more of the following reasons:"
+3 "There are no eligible device units in the system."
+4 "An IOA is in a condition that makes the disk units attached to\
+ it read/write protected. Examine the kernel messages log\
+ for any errors that are logged for the IO subsystem\
+ and follow the appropriate procedure for the reference code to\
+ correct the problem, if necessary."
+5 "Not all disk units attached to an advanced function IOA have\
+ reported to the system. Retry the operation."
+6 "The disk units are missing."
+7 "The disk unit/s are currently in use."
+
+$set 236
+1 "Configure a hot spare device"
+2 "Select the subsystems which disk units will be configured as hot spares"
+3 "Type choice, press Enter."
+4 "Select subsystem"
+5 "Unconfigure a hot spare device"
+6 "Select the subsystems which disk units will be unconfigured as hot spares"
+7 "Type choice, press Enter."
+8 "Select subsystem"
+
+$set 240 select_hot_spare
+1 "Select Disk Units to Enable as Hot Spare"
+2 "Type option, press Enter."
+3 "Select"
+4 "Select Disk Units to Disable as Hot Spare"
+5 "Type option, press Enter."
+6 "Select"
+
+$set 245 confirm_hot_spare
+1 "Confirm Enable Hot Spare"
+2 "ATTENTION: Existing data on these disk units will not be preserved."
+3 "Press Enter to continue."
+4 "Cancel to return and change your choice."
+5 "Confirm Disable Hot Spare"
+6 "ATTENTION: Existing data on these disk units will not be preserved."
+7 "Press Enter to continue."
+8 "Cancel to return and change your choice."
+
+$set 300 disk_unit_recovery
+1 "Work with Disk Unit Recovery"
+2 "Concurrent Add Device"
+3 "Concurrent Remove/Replace Device"
+4 "Initialize and format disk unit"
+5 "Reclaim IOA cache storage"
+6 "Rebuild disk unit data"
+7 "Work with resources containing cache battery packs"
+
+$set 301 concurrent_add_device
+1 "Concurrent Device Add"
+2 "Choose a single location for add operations"
+3 "Select"
+
+$set 302 concurrent_remove_device
+1 "Concurrent Device Remove"
+2 "Choose a single location for remove operations"
+3 "Select"
+4 "Concurrent Device Add"
+5 "Choose a single location for add operations"
+6 "Select"
+
+$set 303 process_conc_maint
+1 "Verify Device Concurrent Remove"
+2 "Verify the selected device for concurrent remove operations"
+3 "Press Enter when verification complete and ready to continue"
+4 "Cancel to return and change your choice."
+5 "Verify Device Concurrent Add"
+6 "Verify the seleted device for concurrent add operations"
+7 "Press Enter when verification complete and ready to continue"
+8 "Cancel to return and change your choice."
+9 "Complete Device Concurrent Remove"
+10 "Remove selected device"
+11 "Press Enter when selected device has been removed"
+12 "Cancel to return and change your choice."
+13 "Complete Device Concurrent Add"
+14 "Add device to selected location"
+15 "Press Enter when device has been installed"
+16 "Cancel to return and change your choice."
+
+$set 312 configure_af_device | init_device
+1 "Select Disk Units to format for Advanced Function"
+2 "Select Disk Units to format for JBOD Function"
+3 "Select Disk Units for Initialize and Format"
+4 "Type option, press Enter."
+5 "Select"
+
+$set 313
+1 "Confirm Initialize and Format Disk Unit"
+2 "Press 'c' to confirm your choice for 1=Initialize and format."
+3 "Return to change your choice."
+
+$set 314 dev_init_complete
+1 "Initialize and Format Status"
+2 "You selected to initialize and format a disk unit"
+4 "Please wait for the next screen."
+
+$set 315 reclaim_cache
+1 "Reclaim IOA Cache Storage"
+2 "Select the IOA to reclaim IOA cache storage."
+3 "ATTENTION: Proceed with this function only if directed to from a\
+ service procedure. Data in the IOA cache will be discarded.\
+ Damaged objects may result on the system."
+4 "Type choice, press Enter."
+5 "Reclaim IOA cache storage."
+
+$set 316 confirm_reclaim
+1 "Confirm Reclaim IOA Cache Storage"
+2 "The disk units that may be affected by the function are displayed."
+3 "ATTENTION: Proceed with this function only if directed to from a\
+ service procedure. Data in the IOA cache will be discarded.\
+ Filesystem corruption may result on the system."
+4 "Press c=Confirm to reclaim cache storage."
+5 "Cancel to return to change your choice."
+
+$set 317 confirm_reclaim_warning
+2 "ATTENTION!!! ATTENTION!!! ATTENTION!!! ATTENTION!!!"
+3 "ATTENTION: Proceed with this function only if directed to from a\
+ service procedure. Data in the IOA cache will be discarded.\
+ By proceeding you will be allowing UNKNOWN data loss.\
+ This data loss may or may not be detected by the host operating system.\
+ Filesystem corruption may result on the system."
+4 "Press 's' to continue."
+
+$set 319 reclaim_result
+1 "Reclaim IOA Cache Storage Results"
+2 "IOA cache storage reclamation has completed. Use the number\
+ of lost sectors to decide whether to restore data from the\
+ most recent save media or to continue with possible data loss."
+3 "Number of lost sectors"
+4 "IOA cache storage reclamation has completed. The number of\
+ lost sectors could not be determined."
+
+$set 321 raid_rebuild
+1 "Rebuild Disk Unit Data"
+2 "Select the units to be rebuilt"
+3 "Type choice, press Enter."
+4 "Rebuild"
+
+$set 322 raid_rebuild_fail
+1 "Rebuild Disk Unit Data Failed"
+2 "There are no disk units eligible for the selected operation\
+ due to one or more of the following reasons:"
+3 "There are no disk units that need to be rebuilt."
+4 "The disk unit that needs to be rebuild is not at the right\
+ location. Examine the 'message log' for the exposed unit\
+ and make sure that the replacement unit is at the correct\
+ location."
+5 "Not all disk units attached to an IOA have reported to the\
+ system. Retry the operation."
+6 "All the disk units in a parity set must be the same capacity\
+ with a minumum number of 4 disk units and a maximum of 10 units\
+ in the resulting parity set."
+7 "The type/model of the disk units is not supported for the\
+ requested operation."
+
+$set 323 confirm_raid_rebuild
+1 "Confirm Rebuild Disk Unit Data"
+2 "Rebuilding the disk unit data may take several minutes for\
+ each unit selected."
+3 "Press Enter to confirm having the data rebuilt."
+4 "Cancel to return and change your choice."
+
+$set 330 battery_maint
+1 "Work with Resources Containing Cache Battery Packs"
+2 "Type options, press Enter"
+3 "Force battery pack into error state"
+4 "Display battery information"
+
+$set 341 confirm_force_battery_error
+1 "Force Battery Packs Into Error State"
+2 "ATTENTION: This service function should be run only under the direction\
+ of the IBM Hardware Service Support"
+3 "You have selected to force a cache batter error on an IOA"
+4 "You will have to replace the Cache Battery Pack in each selected IOA to\
+ resume normal operations."
+5 "System performance could be significantly degraded until the cache battery\
+ packs are replaced on the selected IOAs."
+6 "Continue to force the following battery packs into an error state"
+
+$set 332 show_battery_info
+1 "Battery Information"
+2 "Resource Name"
+3 "Serial Number"
+4 "Type"
+5 "PCI Address"
+6 "SCSI Host Number"
+7 "Battery type"
+8 "Battery state"
+9 "Power on time (days)"
+10 "Adjusted power on time (days)"
+11 "Estimated time to warning (days)"
+12 "Estimated time to error (days)"
+13 "Resource Path"
+
+21 "Nickel Cadmium (NiCd)"
+22 "Nickel Metal Hydride (NiMH)"
+23 "Lithium Ion (LiIon)"
+24 "Unknown"
+
+31 "No battery warning"
+32 "Battery warning issued"
+33 "Battery error issued"
+
+$set 401 bus_config
+1 "Work with SCSI Bus Configuration"
+2 "Select the subsystem to change scsi bus attribute."
+3 "Type choice, press Enter."
+4 "change scsi bus attribute"
+
+$set 402 bus_config_fail
+1 "Work with SCSI Bus Configuration Failed"
+2 "There are no SCSI Buses eligible for the selected operation.\
+ None of the installed adapters support the requested\
+ operation."
+
+$set 403 change_bus_attr
+1 "Change SCSI Bus Configuration"
+2 "Current Bus configurations are shown. To change\
+ setting hit 'c' for options menu. Hightlight desired\
+ option then hit Enter"
+3 "Change Setting"
+4 "BUS"
+5 "QAS Capability"
+6 "Host SCSI ID"
+7 "Wide Enabled"
+8 "Maximum Bus Throughput"
+9 "Enable"
+10 "Enabled"
+11 "Disable"
+12 "Disabled"
+13 "Yes"
+14 "No"
+
+21 "Confirm Change SCSI Bus Configuration"
+22 "Confirming this action will result in the following\
+ configuration to become active."
+23 "Confirm Change SCSI Bus Configration"
+
+$set 458 driver_config
+1 "Adapter Driver Configuration"
+2 "Select subsystem to change driver configuration"
+3 "Type choice, press Enter"
+4 "change driver configuration"
+
+$set 459 change_driver_config
+1 "Change Driver Configuration"
+2 "Current Driver configurations are shown. To change\
+ setting, type in new value then hit Enter"
+3 "Current Verbosity"
+4 "New Verbosity"
+
+$set 500 log_menu
+1 "Kernel Messages Log"
+2 "View most recent IBM Storage error messages"
+3 "View IBM Storage error messages"
+4 "View all kernel error messages"
+5 "View sisconfig error messages"
+6 "Set root kernel message log directory"
+7 "Set default editor"
+8 "Restore defaults"
+9 "View IBM boot time messages"
+
+$set 501 kernel_root
+1 "Kernel Messages Log Root Directory"
+2 "Enter new directory and press Enter"
+3 "Current root directory:"
+4 "New root directory:"
+
+$set 502 confirm_kernel_root
+1 "Confirm Root Directory Change"
+2 "Press 'c' to confirm your new kernel root directory choice."
+3 "To return to the log menu without changing the root directory, choose 'q'."
+4 "New root directory:"
+
+$set 503 set_default_editor
+1 "Kernel Messages Editor"
+2 "Enter new editor command and press Enter"
+3 "Current editor:"
+4 "New editor:"
+
+$set 504 confirm_set_default_editor
+1 "Confirm Editor Change"
+2 "Press 'c' to confirm your editor choice"
+3 "To return to the log menu without changing the editor, choose 'q'."
+4 "New editor:"
+
+$set 888 screen status strings
+1 ""
+2 "Invalid option specified"
+3 "Screen paged up"
+4 "Already at top"
+5 "Screen paged down"
+6 "Already at bottom"
+10 "No devices to show details for"
+15 "The selection is not valid"
+16 "Error. More than one unit was selected."
+17 "Invalid option. No devices selected."
+18 "Start Parity Protection completed successfully"
+19 "Start Parity Protection failed."
+20 "Stop Parity Protection failed"
+21 "Stop Parity Protection completed successfully."
+25 "Error: number of devices selected must be a multiple of %d"
+26 "Include failed"
+27 "Include Unit completed successfully"
+28 "Rebuild started, view Parity Status Window for rebuild progress"
+29 "Rebuild failed"
+30 "Device concurrent maintenance failed"
+31 "Device concurrent maintenance failed, device in use"
+32 "Device concurrent maintenance completed successfully"
+33 "No units available for initialize and format"
+34 "Initialize and format completed successfully"
+35 "Initialize and format failed"
+36 "Reclaim IOA Cache Storage completed successfully"
+37 "Reclaim IOA Cache Storage failed"
+38 "No Reclaim IOA Cache Storage is necessary"
+39 "No Reclaim IOA Cache Storage performed"
+40 "Rebuild started, view Parity Status Window for rebuild progress"
+41 "Rebuild failed"
+42 "The selected battery packs have successfully been placed into an error state."
+43 "Attempting to force the selected battery packs into an error state failed."
+44 "No configured resources contain a cache battery pack."
+
+45 "Change SCSI Bus configurations completed successfully"
+46 "Change SCSI Bus configurations failed"
+47 "Change Device Driver Configurations completed successfully"
+48 "Change Device Driver Configurations failed"
+
+49 "No units available for initialize and format"
+50 "Initialize and format completed successfully"
+51 "Initialize and format failed"
+
+52 "No devices available for the selected hot spare operation"
+53 "Enable Device as Hot Spare Completed successfully"
+54 "Disable Device as Hot Spare Completed successfully"
+55 "Configure a hot spare device failed"
+56 "Unconfigure a hot spare device failed"
+
+57 "Change Device Driver Configurations completed successfully"
+58 "Change Device Driver Configurations failed"
+
+59 "Invalid directory"
+60 "Root directory changed to %s"
+61 "Root directory unchanged"
+62 "Editor changed to %s"
+63 "Editor unchanged"
+64 "Default log values restored"
+65 "Editor returned %d. Try setting the default editor."
+
+$set 999 empty set used for screens without displays